Inspection Report

Florida DBPR Inspection Report
Completed

RUNABOUT BREWING

4721 S ORANGE AVE · ORLANDO · Orange County · FL 32806

Restaurant history →

Inspection Summary

Inspection dateApril 15, 2025
Inspection typeRoutine – Food
Inspection classFood
DBPR dispositionCall Back – Complied
Resultmet_inspection_standards
Inspection number3579209
Visit number2
Inspection Visit ID10760813
DBPR license5815358

Violation Summary

Counts reported for this inspection visit.

Full inspector observations available
1 High Priority1 Intermediate1 Basic0 Critical0 Non-Critical3 Total
MEMBER-ONLY COMPARISON

See what changed since the last inspection.

Sign in or create a free account to browse without ads and see newly cited, repeated, and no-longer-cited violation categories.

Unlock comparison

All DBPR Inspector Observations

3 full violation description(s) documented by the inspector during this visit.

High Priority 1

#2High Priority29-42-4

High Priority – – From initial inspection : High Priority – Vacuum breaker missing at mop sink faucet or on fitting/splitter added to mop sink faucet. For splitter on mop sink and hose Bibb next to mop sink **Warning** – From follow-up inspection 2025-04-15: **Time Extended**

Warning

Intermediate 1

#3Intermediate51-16-7

Intermediate – – From initial inspection : Intermediate – No plan review submitted and approved – renovations were made or are in progress. Must submit plans and plan review application to DBPR H and R Plan Review office located at 2601 Blair Stone Rd., Tallahassee, FL 32399-1011. Plans must be submitted AND approved within 60 days. The direct link to the Plan Review page is https://www2.myfloridalicense.com/hotels-restaurants/licensing/plan-review/. Facility has extended the bar area to a U shape additional area of the bar for raw oysters. Additional equipment added into kitchen area, dish machine, oven, coolers, fryer, Salamander, expo/server area. Hand sink removed from original straight bar area (2 compartment sink added in place of hand sink) Walk in cooler in back storage prep area removed. Warning** **Warning** – From follow-up inspection 2025-04-15: Facility has submitted update plans. Still waiting for approval **Time extended until next unannounced inspection **Time Extended**

Warning

Basic 1

#1Basic51-09-4

Basic – – From initial inspection : Basic – Establishment did not report seating change that affects the license fee, Clean Indoor Air Act, sewage system approval or other related requirements. Facility has increased seats from 68 seats to 145 seats. 63 seats inside and 82 seats outside Provided form **Warning** – From follow-up inspection 2025-04-15: Per owner paperwork signed off for approval of 148. Paperwork unable to be observed at this time Time extended until next unannounced inspection **Time Extended**

Warning

Inspector observations synchronized from DBPR on September 11, 2026 12:17 PM.

Violation category totals
Category 29 · Plumbing, mop sink, filters and backflow prevention
1 observation(s)
Category 51 · Other sanitary and safe-operation conditions
2 observation(s)

Inspection records and inspector observations reflect conditions documented by DBPR at the time of the inspection and may not reflect current conditions.