Inspection Report

Florida DBPR Inspection Report
Warning

SUBWAY 11771

2851 GARDEN ST · TITUSVILLE · Brevard County · FL 32796

Restaurant history →

Inspection Summary

Inspection dateDecember 22, 2023
Inspection typeRoutine – Food
Inspection classFood
DBPR dispositionWarning Issued
Resultfollow_up_required
Inspection number3346882
Visit number1
Inspection Visit ID8366142
DBPR license1504375

Violation Summary

Counts reported for this inspection visit.

Full inspector observations available
2 High Priority1 Intermediate2 Basic0 Critical0 Non-Critical5 Total
MEMBER-ONLY COMPARISON

See what changed since the last inspection.

Sign in or create a free account to browse without ads and see newly cited, repeated, and no-longer-cited violation categories.

Unlock comparison

All DBPR Inspector Observations

5 full violation description(s) documented by the inspector during this visit.

High Priority 2

#3High Priority01B-02-5

High Priority – Stop Sale issued on time/temperature control for safety food due to temperature abuse. In steamwell on front line. meatballs (85F – Reheating). Operator stated that the meatballs were placed in well at 9am.

Stop Sale
#4High Priority03E-04-5

High Priority – Time/temperature control for safety, commercially processed food in the process of reheating for hot holding for more than 2 hours has not reached 135 degrees Fahrenheit. In steamwell on front line. meatballs (85F – Reheating). Operator stated that the meatballs were placed in well at 9am. SEE STOP SALE

Stop Sale

Intermediate 1

#5Intermediate11-26-1

Intermediate – No proof provided that food employees are informed of their responsibility to report to the person in charge information about their health and activities related to foodborne illnesses. Operator is unable to provide proof of documentation. Does not have access to onboarding system to verify availability. Emailed state form for alternative until company policy can be made accessible. **Warning**

Warning

Basic 2

#1Basic36-37-5

Basic – Ceiling not smooth, nonabsorbent and easily cleanable in food preparation, food storage, or warewashing areas. Ceiling tiles over line and prep areas are perforated acoustic tiles

#2Basic14-17-4

Basic – Walk-in cooler/freezer shelves with rust that has pitted the surface. Walk in cooler shelves are rusted and chipping

Inspector observations synchronized from DBPR on October 16, 2026 12:13 PM.

Violation category totals
Category 1 · Approved food source
1 observation(s)
Category 3 · Time/temperature control for safety food
1 observation(s)
Category 11 · Employee health knowledge / ill employees
1 observation(s)
Category 14 · Food-contact and nonfood-contact surface design/maintenance
1 observation(s)
Category 36 · Floors, walls, ceilings, attached equipment and ventilation
1 observation(s)

Inspection records and inspector observations reflect conditions documented by DBPR at the time of the inspection and may not reflect current conditions.