35A-02-6High Priority – – From initial inspection : High Priority – Live, small flying insects in kitchen, food preparation area, food storage area and/or bar area. Observed approximately 5 total live flying insects in establishment in following area: 2 live flying insects at three compartment sink 3 live flying insects at dish machine area on wall **Warning** – From follow-up inspection 2024-06-28: Still the same. Observed approximately 5 live total flying insects in establishment: 1 flying insects at dish machine area on wall 4 live flying insects at three compartment sink area Operator has pest control devices installed **Admin Complaint** **Corrective Action Taken**
28-26-5High Priority – – From initial inspection : High Priority – Sewage/wastewater backing up through floor drains. Under dish machine due to drain sink not draining. Area isolated only under dish machine. All other floor drains working properly **Warning** – From follow-up inspection 2024-06-28: Still the same **Time Extended**
03A-02-5High Priority – – From initial inspection : High Priority – Time/temperature control for safety food cold held at greater than 41 degrees Fahrenheit. Roasted corn and black beans (47-51F – Cold Holding), stored in second make table flip top reach in cooler on cook line. Lid was left open and employee closed lid **Corrective Action Taken** **Warning** – From follow-up inspection 2024-06-28: Still the same. Roasted corn and black beans (47-51F – Cold Holding), stored in second make table flip top reach in cooler on cook line. Lid was left open and employee closed lid and placing bags of ice on top. Manager stated temperature was taken in morning and was 41F and below but unit lid left open during service **Admin Complaint**
29-42-4High Priority – – From initial inspection : High Priority – Vacuum breaker missing at mop sink faucet or on fitting/splitter added to mop sink faucet. Missing back flow preventer at mop sink on non-chemical side of splitter **Warning** – From follow-up inspection 2024-06-28: Still the same. Operator installed back flow preventer but in wrong spot **Time Extended**
Basic 1
33-20-4Basic – – From initial inspection : Basic – Grease on the ground and/or pad around grease receptacle. Observed grease and build up on ground outside back door area on asphalt. Manager aware of situation and will have it cleaned up. **Warning** – From follow-up inspection 2024-06-28: Still the same **Time Extended**